volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Water Pump|Specifications|Page 3144 > < Water Pump|Specifications
Page 1
background image

Water Pump: Testing and Inspection

After-run coolant pump -V51- 

The after-run coolant circulation pump -arrows- is generally activated for 10 - 12 minutes about 15 seconds after ignition is shut off. If the coolant
temperature is above 92 C, the radiator fan -V7- will also be turned on.

Special tools and equipment 

-

Hand multimeter VAG 1526 or multimeter VAG 1715

-

Wiring diagram

Check conditions 

-

Fuse 34 must be OK.

Test sequence 

-

Start engine and idle briefly.

-

Switch ignition off.

Continued coolant circulation pump (V51) must start after about 15 seconds.

If pump does not run:
-

Pull 2-pin connector off pump.

-

Attach multimeter for measuring voltage to contacts 1+2 of connector.
Specification: 11 - 15V 

If the specification is obtained:
-

Replace continued coolant circulation pump.

If no voltage is present:
-

Check wiring from relay plate to continued coolant circulation pump.

Water Pump|Specifications|Page 3144 > < Water Pump|Specifications