Condenser Fan: Description and Operation
Climatronic

A/C Coolant Fan Second Stage

-

F129 A/C Pressure Switch

-

J26 Coolant Fan Control Relay

-

F18 Coolant Fan Control Thermoswitch

-

J279 First Speed Coolant Fan Control Relay

-

J280 Second Speed Coolant Fan Control Relay

-

N39 Coolant Fan Control (FC) Series Resistance

-

V7 Coolant Fan

When the manual A/C system is turned on, -J26- actuates First Speed (FC) Relay -J279- which actuates the Coolant Fan -V7- via -N39-. -J279- is also
actuated by the coolant fan control thermoswitch -F18- if coolant temperatures reach between 92° and 97°C. Additionally, -F18- will actuate the
Second Speed Coolant (FC) Relay -J280- if coolant temperatures reach between 99° and 105°C. Second Speed bypasses the Coolant Fan Series
Resistor -N39- when actuating -V7-. For more specific temperature information on -F18-, consult the repair manual.

A/C Pressure Switch -F129- will actuate the Second Speed Coolant (FC) Relay -J280- when pressure increases in the refrigerant circuit, regardless of
-F18-.