Check wiring for open circuit between ECM/test box and 4-pin HO2S harness connector (to ECM).
-

Connector terminal 2 to ECM/test box socket 27

-

Specified value: max. 1.5 Ohms

-

Check wiring at HO2S harness connector terminals 3 and 4 for short circuit to terminals 1 and 2 using wiring diagram.
Specified value: Infinity Ohms

If the specification is attained:

-

Check wiring between terminal 1 and fuel pump relay -J17- using appropriate wiring diagram.

-

Check readiness code. If Diagnostic Trouble Code (DTC) memory has been erased, or ECM was disconnected, generate new readiness code.   
See: Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes

 
If wiring is OK:

-

Replace Motronic ECM -J220-.  See: Engine Control Module/Service and Repair

With Generic Scan Tool

Oxygen sensor heater for oxygen sensors behind Three Way Catalytic Converter (TWC), checking

NOTE: When servicing terminals in harness connector of Heated Oxygen Sensor (HO2S), use only goldplated terminals.

Recommended special tools and equipment

-

V.A.G 1526 multimeter or V.A.G 1715 multimeter

-

V.A.G 1594 Connector test set

-

Wiring diagram

Test requirements

-

The respective fuses of Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) -G130- and Oxygen Sensor (O2S) 2 Behind Three
Way Catalytic Converter (TWC) -G131- must be OK:

-

Ignition switched off.

Test sequence

-

Disconnect 4-pin harness connector to the respective oxygen sensor:

Oxygen Sensor & O2S Control Before Three Way Catalytic Converter (TWC), Checking|Page 4483 > < Oxygen Sensor & O2S Control Before Three Way Catalytic Converter (TWC), Checking|Page 4481