volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor & O2S Control Before Three Way Catalytic Converter (TWC), Checking|Page 4901 > < Oxygen Sensor & O2S Control Before Three Way Catalytic Converter (TWC), Checking|Page 4899
Page 11
background image

-

Check wiring for open circuit between ECM/test box and 4-pin HO2S harness connector (to ECM).
Connector terminal 3 to ECM/test box socket 25
Connector terminal 4 to ECM/test box socket 26
Specified value: max. 1.5 Ohms

-

Check wiring for short circuits between terminals of 4-pin connector, and ECM/test box.
Connector terminal 4 to ECM/test box socket 25
Specified value: Infinity Ohms

-

Check wiring for short circuits to wiring harness shielding.
Connector terminal 4 to ECM/test box socket 14
Connector terminal 3 to ECM/test box socket 14
Specified value: Infinity Ohms

If wiring is OK:
-

Replace Motronic ECM -J220-.  See: Engine Control Module/Service and Repair

HO2S wiring, bank 2, sensor 1, checking

-

Connect VAG1598/22 test box to ECM harness connector.

Oxygen Sensor & O2S Control Before Three Way Catalytic Converter (TWC), Checking|Page 4901 > < Oxygen Sensor & O2S Control Before Three Way Catalytic Converter (TWC), Checking|Page 4899