Leak Detection Pump: Testing and Inspection
With Manufacturer's Scan Tool

Leak Detection Pump (LDP), checking 

Special tools and equipment 

-

Fluke 83 multimeter

-

VAG 1527B voltage tester

-

VW1 594 connector test kit

-

Wiring diagram

Electrically checking leak detection pump 

-

Disconnect 3-pin harness connector of leak detection pump -V144-.

-

Connect Fluke 838 multimeter to measure resistance between terminal -1- and -3- of -V144-.
Specification: 640 - 720 Ohms 

-

Connect Fluke 838 multimeter to measure resistance between terminals -2- and -3- of -V144-.
Specification: 17.5 - 27.5 Ohms 

If the specifications are not attained:
-

Replace leak detection pump -V144-.

 
 
Checking voltage supply 

Test conditions 

-

Fuse 29 OK.

Test sequence 

-

Disconnect 3-pin harness connector of leak detection pump -V144-.

-

Connect VAG 1527B voltage tester between connector contact 3 (positive) and engine Ground (GND).

-

Start engine and run at idling speed: