Bank 1, sensor 1.

-

Bank 2, sensor 1.

If voltage is OK:
-

Replace respective Heated Oxygen Sensor (HO2S).
-

Heated Oxygen Sensor -G39- Bank.

-

Heated Oxygen Sensor -G108- Bank 2.

-

Check readiness code. If Diagnostic Trouble Code (DTC) memory has been erased, or ECM was disconnected, generate new readiness code.   
See: Computers and Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Output Diagnostic Test Mode (DTM) (Function
03)

HO2S wiring, bank 1, sensor 1, checking

-

Connect VAG1598/22 test box to ECM harness connector.

-

Disconnect 4-pin connector (black) for HO2S -G39- (arrow).

Oxygen Sensor & O2S Control Before Three Way Catalytic Converter (TWC), Checking|Page 3607 > < Oxygen Sensor & O2S Control Before Three Way Catalytic Converter (TWC), Checking|Page 3605