volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor & O2S Control Before Three Way Catalytic Converter (TWC), Checking|Page 3644 > < Oxygen Sensor & O2S Control Before Three Way Catalytic Converter (TWC), Checking|Page 3642
Page 20
background image

-

Connect multimeter US1119 (Fluke 83 or equivalent) between harness connector terminals 3 and 4 (to ECM), using adapter cables from VW1594
connector test kit.

-

Start engine and measure voltage. 
Specified value: 0.40 to 0.50 volts

-

Switch ignition off.

If voltage is NOT OK:

-

Check HO2S wiring.
Bank 1, sensor 2
Bank 2, sensor 2

If voltage is OK:

-

Replace respective O2S behind TWC.
Bank 1, sensor2 -G130-
Bank 2, sensor 2 -G131-

-

Check readiness code. If Diagnostic Trouble Code (DTC) memory has been erased, or ECM was disconnected, generate new readiness code.   
See: Computers and Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Output Diagnostic Test Mode (DTM) (Function
03)

O2S wiring bank 1, sensor 2, checking

-

Connect VAG1598/22 test box to ECM harness connector.

Oxygen Sensor & O2S Control Before Three Way Catalytic Converter (TWC), Checking|Page 3644 > < Oxygen Sensor & O2S Control Before Three Way Catalytic Converter (TWC), Checking|Page 3642