volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor & O2S Control Before Three Way Catalytic Converter (TWC), Checking|Page 1481 > < Oxygen Sensor & O2S Control Before Three Way Catalytic Converter (TWC), Checking|Page 1479
Page 1
background image

Oxygen Sensor: Testing and Inspection
Oxygen Sensor Aging, Bank 1, Sensor 1, Checking

Oxygen Sensor (O2S) aging, bank 1, sensor 1, checking

Special tools and equipment

VAG1551 or VAG1552 Scan Tool (ST) with VAG1551/3 adapter cable

Checking requirements

-

Engine coolant temperature at least 85 °C (185 °F) See VAG1551 scan tool function 08, display group 004, display field 3

Checking, function

-

Connect VAG1551 or VAG1552 scan to( and press buttons -0- and -1- to insert "Engine Electronics" address word 01 (engine running at idle),
Refer to "Scan Tool Testing/Scan Tool Connecting and Initial Checks/Connecting VAG1551/VAG1552 Scan Tool" under "Engine", See:
Powertrain Management/Computers and Control Systems/Testing and Inspection 

Indicated on display

Rapid data transfer

HELP

Select function XX

-

Press buttons -0- and -4- to select "Basic Setting" function 04, and press -Q- button to confirm input.

Indicated on display

Basic Setting

HELP

Input display group number XXX

-

Press buttons -0-, -3- and -4- to input display group number 34 (034), and press -Q- button to confirm input.

Indicated on display (1-4 = display fields)

System in Basic Setting 34

-> 

1 2 3 4

-

Increase engine speed to 1800-2200 RPM.

-

Maintain engine speed at 1800-2200 RPM and compare display with specified values for O2S aging (before TWC) in display fields 3 and 4).

NOTE:  To be sure that the temperature is within the specified range, the specified RPM has to be maintained for at least 1 minute Observe O2S test
status in display field 4.

Oxygen Sensor & O2S Control Before Three Way Catalytic Converter (TWC), Checking|Page 1481 > < Oxygen Sensor & O2S Control Before Three Way Catalytic Converter (TWC), Checking|Page 1479