background image

-

Check wires between test box and 4-pin connector to Engine Control Module (ECM) for open circuit according to wiring diagram.
Wire resistance: max: 1.5 Ohms

Vehicles with engine code AHA

Vehicles with engine code ATQ

Continuation for all vehicles

-

Also check wires for short circuit to B+ or Ground (GND).
Specified value: Infinity Ohms

If no malfunctions are found in wires:

-

Replace Motronic Engine Control Module (ECM) -J220-.

With Manufacturer's Scan Tool

Oxygen Sensor (O2S) and Oxygen Sensor (O2S) control behind TWC, checking

Special tools and equipment

-

VAG1551 or VAG1552 Scan Tool (ST) with VAG1551/3 adapter cable

-

VAG1598/22 test box

-

Multimeter US1119 (Fluke 83 or equivalent)

-

VW1594 connector test kit

-

Wiring diagram

Checking requirements

-

Throttle valve control module adapted to ECM.

-

Exhaust system free of leaks

-

Engine coolant temperature at least 85°C (185°F) See VAG1551 scan tool function 08, display group 004, display field 3

Checking function

-

Connect VAG1551 or VAG1552 scan tool and press buttons -0- and -1- to insert "Engine Electronics" address word 01 (with engine running at
idle),  See: Powertrain Management/Computers and Control Systems/Testing and Inspection 

Indicated on display

Rapid data transfer

HELP

Select function XX

-

Press buttons -0- and -8- to select "Read Measuring Value Block" function 08, and press -Q- button to confirm input.

Indicated on display

Oxygen Sensor & O2S Control Before Three Way Catalytic Converter (TWC), Checking|Page 1501 > < Oxygen Sensor & O2S Control Before Three Way Catalytic Converter (TWC), Checking|Page 1499