VAS 5051 vehicle diagnosis, testing and information system

Test conditions

-

Fuses 13, 29, 32, 34 and 43 OK.

-

Battery 11.5 volts.

-

Ground (GND) connection from engine to body OK.

-

All electrical consumers, e.g. lights and rear window heating switched off.

-

Air conditioning off.

-

Selector lever must be in position "P" or "N" on vehicles with an automatic transmission.

Work sequence

-

Connect Scan Tool (ST) VAS 5051 using adaptor cable VAS 5051/1 or VAS 5051/3 as follows:

-

Push adaptor cable into Data Link Connector (DLC).

-

Depending on function:

-

Switch ignition on

-

Start engine See Table "Selectable functions". 

NOTE:

-

In functions 04 - Basic setting 08 - Read data block, display zones will be listed from top to bottom.

-

If display does not indicate as described in work sequence:
See Operating instructions for vehicle diagnosis, testing and information system VAS 5051. 

Indicated on display: