volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Heated Oxygen Sensor and Oxygen Sensor Control, Checking|Page 570 > < Diagram Information and Instructions|Page 567
Page 1
background image

Oxygen Sensor: Testing and Inspection
Heated Oxygen Sensor and Oxygen Sensor Control, Checking

HEATED OXYGEN SENSOR AND OXYGEN SENSOR CONTROL, CHECKING

Special tools, testers and auxiliary items

-

VAG 1551 Scan Tool (ST) or vehicle system tester VAG 1552 with VAG 1551/3 adapter cable

-

VAG 1598/18 test box

-

Multimeter (Fluke 83 or equivalent)

-

VW 1594 connector test kit

-

Wiring diagram

Checking conditions

-

Coolant temperature at least 80 °C (176 °F)

-

Exhaust system free of leaks between cylinder head and Three Way Catalytic Converter (TWC)

Functional check

Connect VAG 1551 scan tool (VAG 1552) and select "Rapid data transfer" operating mode.

-

Press buttons -0- and -1- to insert "Engine Electronics" address word 01. Carry out selection at idle. Refer to "On-Board Diagnostic". See:
Powertrain Management/Computers and Control Systems/Testing and Inspection 

Indicated on display

Rapid data transfer

HELP

Select function XX

Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.

Press -Q- button to confirm input.

Indicated on display

Read measuring value block

HELP

Input display group number XXX

NOTE:  If something different is indicated on the display: 
See Scan tool operating instructions.

-

Press -0-, -0- and -1- to input display group number 001.

-

Press -Q- button to confirm input.

Indicated on display (1, 2, 3 and 4 = Display fields)

Read measured value block 1    

->    

1

2

3

4 

Read oxygen sensor factor in display field 3.

Specification: display fluctuates around 1

If oxygen sensor factor does not fluctuate:

Carry out road test to clean HO2S probe, then repeat check.

If the oxygen sensor factor specification is not attained:

Check oxygen sensor heating. See: Oxygen Sensor Heating, Checking 

If the displayed value remains constant:

Press -> button.

Press buttons -0- and -6- to select "End Output" function 06.

Press -Q- button to confirm input.

Switch ignition off.

Continue check according to following table.

Heated Oxygen Sensor and Oxygen Sensor Control, Checking|Page 570 > < Diagram Information and Instructions|Page 567