and Readiness Codes

If specified value is obtained:

-

Check Ground (GND) activation of the respective oxygen sensor heater.

-

Connect test box to control module wiring harness, connect test box for wiring test.  See: Powertrain Management/Computers and Control
Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/With Generic Scan Tool/Test Box,
Connecting For Wiring Test

-

Check wires between test box and 4-pin connector to Engine Control

Module (ECM) for open circuit according to wiring diagram.
Wire resistance: max: 1.5 Ohms

Vehicles with engine code AHA

Vehicles with engine code ATQ

Continuation for all vehicles

-

Also check wires for short circuit to B+ or Ground (GND).
Specified value: Infinity Ohms

-

Check wire between 4-pin connector terminal 1 and Fuel Pump (FP) Relay -J17- for open circuit according to wiring diagram.
Wire resistance: max: 1.5 Ohms

If no malfunctions are found in wires:

-

Replace Motronic Engine Control Module (ECM) -J220-.

With Manufacturer's Scan Tool

Oxygen Sensor Heater For Heated Oxygen Sensors (HO2S) Before Catalytic Converter, Checking

When servicing terminals in harness connector of Heated Oxygen Sensor (HO2S), use only gold-plated terminals.

Special tools and equipment

-

V.A.G 1551 Scan Tool (or VAG 1552 mobile scan tool) with VAG 1551/3 cable

-

VAG 1598/31 test box

-

VAG 1526 multimeter or VAG 1715 multimeter

-

VAG 1594 connector test kit

-