volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Adjusting cable at footwell/defroster flap > < Evaluating checks of air conditioning system pressure switch F129
Installing and adjusting cables
   
Installing and adjusting cables
  Note
t  First connect cables to removed controls, then adjust cables at air conditioner levers and secure them.
t  Place Bowden cable sheath against stops on controls and secure.
t  Adjust cables at flap levers with controls installed.
t  When control knobs are turned, all flaps must audibly contact stop.
1 - Footwell/defroster flap cable
q   From air distribution rotary knob to footwell/defroster flap.
q   Black sheath.
q   Adjust cable at footwell/defroster flap → Chapter.
2 - Central flap cable
q   From air distribution rotary control to central flap.
q   Yellow sheath.
q   Adjusting cable at central flap → Chapter.
3 - Temperature flap cable
q   From temperature rotary knob to temperature flap.
q   Blue sheath.
q   Adjusting cable at temperature flap → Chapter.

   

Adjusting cable at footwell/defroster flap > < Evaluating checks of air conditioning system pressure switch F129