Removing extraction and charging valve, high pressure side |
WARNING Danger of freezing injuries. |
If refrigerant circuit has not been evacuated, refrigerant may escape. |
Extract refrigerant before opening refrigerant circuit. |
|
–
| Extract refrigerant from refrigerant circuit, e.g. with air conditioning service station -VAS 6007A- before replacing valve -3-. |
For additional service stations ⇒ V.A.G Workshop Equipment Catalogue. |
Note t
| Releasing refrigerant into the environment is a punishable offence. |
t
| All components of the refrigerant circuit which have been opened must be sealed with suitable plugs to prevent moisture penetration. |
1 - | Connection with internal thread |
2 - | O-ring; 10.8 mm; 1.8 mm |
3 - | Extraction and filling valve with groove and internal thread for cap |
|
|
|