Vehicle | Adapters required for refrigerant pipes to air conditioner compressor | Adapters required for refrigerant pipes to receiver and 2nd evaporator | Miscellaneous |
Transporter 7H 2004 ► | t
| Air conditioner compressor 7H0 820 805 E low-pressure side adapter -VAS 6338/12-, high-pressure side adapter -VAS 6338/3- |
t
| Air conditioner compressor 7H0 820 803 C low-pressure side adapter -VAS 6338/7-, high-pressure side adapter -VAS 6338/2- |
| –
| Remove dryer cartridge and seal receiver. |
–
| After rinsing, install a new dryer cartridge. |
t
| Sealing adapter -VAS 6338/5- for front refrigerant circuit. |
t
| Sealing adapter -VAS 6338/11- for front refrigerant circuit. |
t
| Low-pressure line for 2nd evaporator adapter -VAS 6338/3- |
t
| High-pressure line for 2nd evaporator adapter -VAS 6338/4- |
| –
| To vehicle identification number 20000, drill out expansion valve → Anchor |
–
| From vehicle identification number 20001, install adapter -VAS 6338/56- in place of front expansion valve |
–
| After purging, install a new expansion valve. |
–
| Install adapter -VAS 6338/33- in place of expansion valve on 2nd evaporator |
–
| After purging, install a new expansion valve. |
|
Transporter 7J 2004 ► | t
| Air conditioner compressor 7H0 820 805 E low-pressure side adapter -VAS 6338/12-, high-pressure side adapter -VAS 6338/3- |
t
| Air conditioner compressor 7H0 820 803 C low-pressure side adapter -VAS 6338/7-, high-pressure side adapter -VAS 6338/2- |
t
| Air conditioner compressor 7H0 820 805 D low-pressure side adapter -VAS 6338/52-, high-pressure side adapter -VAS 6338/51- |
| –
| Remove dryer cartridge and seal receiver. |
–
| After rinsing, install a new dryer cartridge. |
t
| Sealing adapter -VAS 6338/5- for front refrigerant circuit. |
t
| Sealing adapter -VAS 6338/11- for front refrigerant circuit. |
t
| Low-pressure line for 2nd evaporator adapter -VAS 6338/3- |
t
| High-pressure line for 2nd evaporator adapter -VAS 6338/4- |
| –
| To vehicle identification number 5000, drill out expansion valve → Anchor |
–
| From vehicle identification number 5001, install adapter -VAS 6338/56- in place of front expansion valve |
–
| After purging, install a new expansion valve. |
–
| Install adapter -VAS 6338/56- in place of expansion valve on 2nd evaporator |
–
| After purging, install a new expansion valve. |
|
Transporter 2010 ►; Multivan 2010 ►; California 2010 ►; Caravelle 2010 ►; Amarok 2011 ► | t
| Low-pressure side adapter -VAS 6338/12- |
t
| High-pressure side adapter -VAS 6338/3- |
| –
| Remove dryer cartridge and seal receiver. |
–
| After rinsing, install a new dryer cartridge. |
–
| On Amarok model, rinse receiver and then replace condenser. Reason: Dryer cartridge is not yet offered as a replacement part. |
t
| Sealing adapter -VAS 6338/5- for front refrigerant circuit. |
t
| Sealing adapter -VAS 6338/11- for front refrigerant circuit. |
t
| Low-pressure line for 2nd evaporator adapter -VAS 6338/3- |
t
| High-pressure line for 2nd evaporator adapter -VAS 6338/4- |
| –
| Install adapter -VAS 6338/56- in place of expansion valve (or a drilled out expansion valve → Anchor) |
–
| After purging, install a new expansion valve. |
|
Crafter 2006 ► | t
| Air conditioner compressor 2E0 820 803 A low-pressure side adapter -VAS 6338/12-, high-pressure side adapter -VAS 6338/3- |
t
| Air conditioner compressor 2E0 820 805 low-pressure side adapter -VAS 6338/7-, high-pressure side adapter -VAS 6338/3- |
| Receiver–
| Can be flushed through. |
–
| After purging, install a new receiver. |
t
| Sealing adapter -VAS 6338/5- for front refrigerant circuit. |
t
| Sealing adapter -VAS 6338/11- for front refrigerant circuit. |
t
| Low-pressure line for 2nd evaporator adapter -VAS 6338/3- |
t
| High-pressure line for 2nd evaporator adapter -VAS 6338/4- |
| –
| After purging, install a new expansion valve. |
|
LT 2 1997 ► | t
| Low-pressure side adapter -VAS 6338/7- |
t
| High-pressure side adapter -VAS 6338/2- |
| –
| Remove receiver and bridge refrigerant pipes. |
–
| Connect two adapters -VAS 6338/29- with hose -VAS 6338/31- together. |
–
| After purging, install a new receiver. |
| –
| Install adapter -VAS 6338/56- in place of expansion valve (or a drilled out expansion valve → Anchor) |
–
| After purging, install a new expansion valve. |
|