Polo Mk3
Engine code AKU |
Display group 013 -idling speed smooth running control- | ||||||
Read measured value block 13 | → | ▾ appears on display | ||||
x.xx mg/H | x.xx mg/H | x.xx mg/H | x.xx mg/H | |||
1 | 2 | 3 | 4 | ▾ display zones | Specification | Evaluation |
Cyl. 4 smooth running control injected quantity | - 2.0…+ 2.0 mg/stroke | → Chapter | ||||
Cyl. 3 smooth running control injected quantity | - 2.0…+ 2.0 mg/stroke | → Chapter | ||||
Cyl. 2 smooth running control injected quantity | - 2.0…+ 2.0 mg/stroke | → Chapter | ||||
Cyl. 1 smooth running control injected quantity | - 2.0…+ 2.0 mg/stroke | → Chapter |