t
| Battery charger -VAS 5095 A- |
Caution Always set battery type 2.4 V/C (volts/battery cell) when charging! This applies for all batteries. |
|
Note The battery must have a temperature of at least 10 °C. |
WARNING It is not permissible to test or charge batteries whose magic eye shows light yellow. Do not slave/jump start the vehicle! |
Danger of explosion when checking and charging or slave/jump starting. |
These batteries must be renewed. |
|
–
| Switch off ignition and all electrical consumers. |
–
| Check setting for battery type on type of battery switch → Chapter. Must be set to 2.4 V/C (volts/battery cell). |
–
| Connect red terminal clamp „+“ of charger unit to positive terminal on battery. |
Note In vehicles with start/stop function and battery monitor control unit -J367- fitted, black terminal clamp „-“ must be connected to body earth. Connecting it to battery negative terminal will cause start/stop system to malfunction. |
–
| Connect black terminal clamp „-“ of battery charger to negative terminal. |
The charge current indicators → Fig.-2- and -3- light up yellow. When only the light emitting diode (LED) -3- lights up yellow, battery is partially discharged (approx. 90 %). |
If the LED lights up green → Fig.-4- the charger has switched to "maintaining charge". The battery is fully charged. |
–
| Remove charger unit terminals from battery terminals. |
|
|
|