volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Self-diagnosis of navigation part in RNS > < Read measured value block
Radio, telephone, navigation
Radio/Navigation system self-diagnosis (RNS)
Display group overview

Break down of display content for display group number 001

Display group 001

Read measured value block 1

◂ Indicated on display

xxx

xxx

xxx

xxx

1

2

3

4

◂ Display zone

Specification

Evaluation

S contact on or off (Radio does not switch off)

S contact on = Display "on".
S contact off = Display "off".


Dimming of lights in %

Light off = "0%"
Light on = "20 - 95%", according to position of lighting control for switches and instruments

Voltage supply in volts

approx. battery voltage

Road speed signal from speedometer

"1" or "0"

Evaluating display group number 001

Display zone

Description

Display

Rectifying fault

Road speed signal from speedometer

"1" or "0"
The display must always jump back and forth between "1" and "0" when a front wheel is being turned.

- Visually check wiring
Check correct location and secure fit of connectors in relevant circuit and at the same time observe the display
If the display content does not change during operation, the fault should be eliminated or the affected component renewed
Erase fault memory
Perform functional check
Interrogate fault memory again

2

Voltage supply in volts

Approx. battery voltage

3

Dimming of lights in %

Light off = display "0%"
Light on = infinitely variable brightness control for switches and instruments with switches and instruments lighting control, display = "20 - 95%", according to position of control.

4

S contact on or off (Radio does not switch off)

S contact on = display "on".
S contact off = display "off".

Break down of display content for display group number 002

Display group 002

Read measured value block 2

◂ Indicated on display

xxx

xxx

xxx

xxx

1

2

3

4

◂ Display zones

Specification

Evaluation

OK, short or open circuit

"OK"

=> page 01-143

Loudspeakers rear

"Lsp. rear"

OK, short or open circuit

"OK"

Loudspeakers front

"Lsp. front"

Evaluating display group number 002

Display zone

Description

Display

Rectifying fault

1

Loudspeakers front

Lsp. front

- Visually check wiring
Check correct location and secure fit of connectors in relevant circuit and at the same time observe the display
If the display content does not change during operation, the fault should be eliminated or the affected component renewed
Perform functional check
Interrogate fault memory again

2

OK, short or open circuit

OK, short circ., open circ.

3

Loudspeakers rear

Lsp. rear

4

OK, short or open circuit

OK, short circ., open circ.

Break down of display content for display group number 003

Display group 003

Read measured value block 3

◂ Indicated on display

xxx

xxx

xxx

xxx

1

2

3

4

◂ Display zones

Specification

Evaluation

Empty1)

OK, short or open circuit

"OK"

=> page 01-145

Aerial

"Aerial"

Passive or active

"Active"

1)     Empty means in this case: Display zone is blank

Evaluating display group number 003

Display zone

Description

Display

Rectifying fault

1

Passive operating aerial or active aerial with integrated amplifier

"Passive" or
"active" aerial

- Visually check wiring
Check correct location and secure fit of connectors in relevant circuit and at the same time observe the display
If the display content does not change during operation, the fault should be eliminated or the affected component renewed
Perform functional check
Interrogate fault memory again

2

Aerial

"Aerial"

3

OK, short or open circuit

OK, short circ., open circ.

4

None

Empty1)

1)     Empty means in this case: Display zone is blank

Break down of display content for display group number 004

Display group 004

Read measured value block 4

◂ Indicated on display

xxx

xxx

xxx

xxx

1

2

3

4

◂ Display zones

Specification

Evaluation

Status telephone mute

"on" or "off"

Telephone

"Telephone"

=> page 01-147

Empty1)


Status control output of active amplifier (DSP)

"0"

1)     Empty means in this case: Display zone is blank

Evaluating display group number 004

Display zone

Description

Display

Rectifying fault

1

Status control output of active amplifier (DSP)

If control output OK = display "0"
If control output not OK = display "1"

- Visually check wiring
Check correct location and secure fit of connectors in relevant circuit and at the same time observe the display
If the display content does not change during operation, the fault should be eliminated or the affected component renewed
Perform functional check
Interrogate fault memory again

2

None

Empty1)

3

Telephone

"Telephone"

4

Status telephone mute mode (pin 2 of multi-pin connector III)

If output active = display "on".
If output inactive = display "off".

1)     Empty means in this case: Display zone is blank

Break down of display content for display group number 005

Display group 005

Read measured value block 5

◂ Indicated on display

xxx

xxx

xxx

xxx

1

2

3

4

◂ Display zones

Specification

Evaluation

Empty1)

Empty1)


=> page 01-149

OK or not OK

"OK"

Communication to CD changer/CD player

"CD connect"

1)     Empty means in this case: Display zone is blank

Evaluating display group number 005

Display zone

Description

Display

Rectifying fault

1

Communication to CD-changer/CD player (even if no CD-changer is coded)

"CD connect"

- Visually check wiring
Check correct location and secure fit of connectors in relevant circuit and at the same time observe the display

2

Communication to CD changer OK or not OK.

"OK"
if a CD changer is connected.

"not OK"
if a CD changer is connected, the display "not OK" is incorrect => Rectifying fault.

"not OK"
if no CD changer is connected, the display "not OK" is correct.

- If the display content does not change during operation, the fault should be eliminated or the affected component renewed
Perform functional check
Interrogate fault memory again

3

None

Empty1)

4

None

Empty1)

1)     Empty means in this case: Display zone is blank

If the displayed values in all display zones are OK:

  • ‒ Press ⇒key.

Note:

After completing the function "Read measured value block", interrogate fault memory => Page 01-124 .

Ending output

  • ‒ Press keys 0 and 6. (The function "End output" is selected with 06.)
 
→ Indicated on display:
Rapid data transfer     Q
06 End output
  • ‒ Confirm entry with key Q.
 
→ Indicated on display:
Rapid data transfer     Help
Enter address word XX
  • ‒ Switch off ignition.
  • ‒ Disconnect fault reader V.A.G 1551.

Self-diagnosis of navigation part in RNS > < Read measured value block