| Connect pressure meter -VAS 5187- as shown. |
–
| Start engine and keep it running slowly. |
–
| Connect Diagnostic operation center -VAS 5051/- and select operational mode “Auto-diagnosis of vehicle”. Next, with address “01”, access engine electronic command unit. |
–
| On the display, press diagnostic funtion “ 08 - read measurement value block”. |
–
| Using the numerical keyboard enter indication group “2” and confirm with key Q. |
–
| Check slow running rotation on identification field 1 |
–
| Rise rotation to 1500 rpm. |
–
| Observe manometer pressure drop. Theoretical value 3.5 bar minimum. |
–
| Press function “ 06 close section ”. |
If nominal value is not reached: |
–
| Replace tandem pump → Chapter, Tandem pump - remove and install. |
Note After removing pressure meter, tighten threaded plug at 25 Nm. Sealing ring must be replaced. |
|
|
|