Connect the Climate control recovery, recycling
and refill set or VAS 6008 -EQ 7098- or similar
equipment to the service valves -arrows- in the cooling
gas loop and aspirate all the gas → Air conditioning
with R134a cooling gas; Rep. gr.00.
Note
t
Contaminating the environment with refrigerant is a punishable
offence.
t
All refrigerant circuit components that are open must be closed
with proper plugs to prevent humidity from entering them.