| Move temperature flap lever -3- to end positions and mark these positions on distribution box (flap fully open -2- and flap fully closed -4-). |
–
| Set actuator -1- to position "Flap closed -4-". |
–
| Close temperature flap (move lever -3- down to stop). |
–
| Insert actuator -1- into mounting -6- and guide in direction of arrow onto distribution box (pin of actuator -1- must engage in track of lever -3-). |
–
| Engage actuator on distribution box -5-. |
–
| Turn temperature knob on control for heated and fresh air to „Cold“ position. Connect flexible shaft to actuator -1-. |
t
| Check function of actuator. |
Note It must be possible to move temperature flap to end positions (markings -2- and -4-) easily and smoothly. |
Adjustment of temperature flap not OK: |
–
| Remove actuator and repeat installation, as described. |
Adjustment of temperature flap OK: |
–
| Install footwell vent and centre console. |
|
|
|