| Pull supply line -1- off output side of fuel filter. |
Note Press in securing ring to release fuel line. |
–
| Connect pressure tester -V.A.G 1318- using connector -V.A.G 1318/23- and adapter set -V.A.G 1318/17- as shown. |
–
| Close pressure gauge shut-off tap (lever at right angles to through-flow direction, position -B-). |
–
| Operate remote control to V.A.G 1348 -V.A.G 1348/3A- for approx. 10 seconds to fill fuel filter and build-up a system pressure of 4 bar. |
–
| Watch pressure drop on pressure gauge. After 10 minutes, pressure must not drop below 3 bar. |
If the pressure drops further: |
–
| Check line connections for leaks. |
If no fault in lines is detected: |
–
| Renew fuel pressure regulator. |
|
|
|