| First pull breather hose -1- from activated charcoal filter on activated charcoal filter system solenoid valve 1 -N80--2-. |
–
| Connect hand vacuum pump VAS 6213 to hose -1- as shown. |
–
| Operate hand vacuum pump V.A.G 6213 several times. Vacuum must not build up. |
–
| Check breather opening -3- on lower activated charcoal filter -4- for soiling, clean if necessary. |
If vacuum does not build up: |
–
| Temporarily seal breather opening -3- and operate vacuum pump again several times. Vacuum must build up. |
If vacuum does not build up: |
–
| Renew activated charcoal filter. |
|
|
|