| Release latch -1- and remove protective cover -2-. |
WARNING There is a danger of injury due to escaping gas. |
The system is pressurised. |
Wear suitable protection such as eye protection and protective gloves. |
Before opening the system place a cloth around the connection. Then release pressure by carefully loosening the connection. |
|
–
| Detach connector and gas line from gas tank valve -N495-. |
–
| Mark installation position of gas tank valve -N495-. |
|
|
|