volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor System - Checking Procedure|Page 2041 > < Oxygen Sensor - Failure Due to Silicone
Page 1
background image

Oxygen Sensor: All Technical Service Bulletins
Oxygen Sensor System - Checking Procedure

Applies To

QUANTUM

5 Cyl CIS

1984

Group

26
Subject

OXS System

Part Identifier N/A

Key Points

Checking procedure

Supercedes Product Circular, Group 26, 84-01

A-63

Number

85-02

June 28, 1985
The OXS system on this vehicle uses a pressure gradient switch.. This switch signals the OXS control unit to operate the frequency valve at an ON/OFF
ratio of 80% during warm up.

A coolant temperature actuated vacuum switch controls the pressure gradient signal to the OXS control unit.

The switch is off after the vehicle is warmed up.

Pressure gradient switch, checking (installed in vehicle) Work sequence

CAUTION

Test should only be made with Siemens 451 or VAG 1367 testers

FIGURE 1

-

connect " + " lead to battery positive terminal

-

connect " - " lead to battery negative terminal

-

connect dwell lead to OXS test connection (blue/white wire) using adapter US 1112

Oxygen Sensor System - Checking Procedure|Page 2041 > < Oxygen Sensor - Failure Due to Silicone