Compressor HVAC: Procedures

A/C Compressor

-

Only start engine after refrigerant circuit has been assembled.

-

After installing a new A/C compressor or fresh refrigerant oil has been filled into compressor (e.g. after blowing through the A/C system), turn
ribbed belt pulley of A/C compressor 10 rotations by hand before starting the engine. This prevents damage to the A/C compressor.

-

If possible start engine only with a filled refrigerant circuit.

NOTE:
-

The A/C compressor is always driven by the ribbed belt pulley (no A/C clutch):
-

If the A/C compressor is blocked, the compressor shaft overload protection is activated. The blockage is mostly recognized by
deformations/bumps on the ribbed belt pulley. In addition, the blockage can be recognized by the abraded rubber in the area of the ribbed
belt pulley.

-

The A/C compressor is equipped with a protected oil supply, this prevents A/C compressor damage in the event that the system is empty.
This means that approximately 40 to 50 cu.cm of refrigerant oil remains in the A/C compressor.

-

The engine may only be started when the refrigerant circuit is installed correctly. For example; if the refrigerant lines are not connected to
A/C compressor, when the engine is running the A/C compressor may heat up (via internal heat generation) so much that the A/C
compressor will be damaged.

-

A/C Compressor Regulator Valve N280 is not activated when the refrigerant circuit is empty and the A/C compressor idles with the engine.

-

If it is necessary to start the engine with a discharged refrigerant circuit:
-

Refrigerant circuit must be fully assembled.

-

At least 1/4 of the prescribed refrigerant oil must be in the A/C compressor.

-

No not rev engine higher than 2000 rpm.

-

The engine should only run as long as is absolutely necessary, maximum 10 minutes.

-

Note the following when starting engine for first time after filling refrigerant circuit:
-

Start engine with A/C compressor switched off ("ECON" mode) and wait until the idling speed stabilizes.

-

Open an instrument cluster vent.

-

Select temperature preset "Lo" on A/C Control Head E87.

-

Now switch A/C compressor on ("Auto" mode) and allow engine to run for 5 minutes at idling speed.