End of diagnosis

Oxygen Sensor 2 After Three Way Catalytic Converter G131, Checking

Oxygen Sensor 2 After Three Way Catalytic Converter G131, Checking

NOTE:

-

Vehicle must be raised before electrical harness connector for the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) G131 is
accessible.

-

When servicing terminals in harness connector of Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) G131, use only
gold-plated terminals.

Special tools, testers and auxiliary items required

-

Multimeter.

-

Wiring diagram.

Test requirements

-

FuseSB12OK.

-

Battery voltage at least 12.5 volts.

-

All electrical consumers such as, lights and rear window defroster, switched off.

-

Vehicles with automatic transmission, shift selector lever into position "P" or "N".

-

A/C switched off.

-

Ground (GND) connections between engine/transmission/chassis OK.

-

Ignition switched off.

Test procedure

-

Perform a preliminary check to verify the customers complaint.  See: Testing and Inspection/Scan Tool Testing and Procedures/Preliminary Check

Start diagnosis

-

Perform the function test in Diagnostic Mode 06.  See: Testing and Inspection/Scan Tool Testing and Procedures/Diagnostic Mode 06 - Read Test
Results For Specific Diagnostic Functions

-

End diagnosis and switch ignition off.

If the specified values are not obtained:

Checking primary voltage

-

Remove the right vehicle floor cover - arrows -

-

Disconnect the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) G131 electrical harness connector - 1 -.

Heated Oxygen Sensor G39, Checking|Page 2558 > < Heated Oxygen Sensor G39, Checking|Page 2556