volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Fuel Delivery, Checking|Page 2774 > < Fuel Delivery, Checking|Page 2772
Page 1
background image

Fuel Pressure: Testing and Inspection
Fuel Injection & Ignition  - Fuel Supply System

Delivery Quantity, Checking

-

Voltage supply OK.

-

Fuel pressure regulator and residual pressure OK.checking    See: Fuel Pressure Regulator and Residual Pressure, Checking

-

Fuel filter OK.

-

Remove fuel filler cap from fuel filler tube.

-

Open the cover of the relay and fuse panel in the engine compartment E-box.

-

Remove fuse SB6 in position F6 on fuse holder.

-

Connect remote control V.A.G 1348/3 A with adapter cable V.A.G 1348/3-3 to the left terminal (in direction of travel) of fuse socket F6 - arrow -.

-

Using insulating tape, tape over the second contact of connection V.A.G 1348/3-3 to prevent a short circuit.

-

Connect alligator clip to vehicle battery B+.

NOTE:  Delivery rate of Fuel Pump (FP) is measured at 4 bar. Therefore the fuel pressure must be checked before measuring the delivery rate.

CAUTION:  Fuel system is under pressure. Wear protective goggles and protective clothing to prevent injuries and contact with skin.
Before removing from hose connection wrap a cloth around the connection. Then release pressure by carefully pulling hose off
connection.

-

Disconnect return line - 1 - from fuel pressure regulator.

NOTE:  Press in securing ring to disengage the fuel line.

-

Connect adapter set V.A.G 1318/17A to fuel pressure regulator and hold end of adapter in a measuring container.

-

Run the remote control V.A.G 1348/3A approximately 5 seconds to fill the fuel filter.

-

Empty the measuring container.

-

Delivery rate of Fuel Pump (FP) is dependent on voltage. Therefore connect multi-meter to battery.

-

Operate remote control for 30 seconds and measure battery voltage.

Fuel Delivery, Checking|Page 2774 > < Fuel Delivery, Checking|Page 2772