Rabbit L5-2.5L (BGP) (2006)
Flat connector system with two retaining tabs:
-
Guide the release tool which fits the terminal housing into release channel on terminal housing.
-
Grasp terminal at wire and push it gently into terminal housing until it stops -arrow-.
NOTE: By pushing terminal in direction of terminal housing, retaining tabs of terminal are lifted off the housing shoulder and can be released
using the release tool.
-
At the same time, push release tool in direction of terminal housing and pull the released terminal out of terminal housing -arrow-.
-
After removing the terminal, release tool can be pulled out of terminal housing again.
Asymmetrical:
-
Guide the release tool which fits the terminal housing into release channel on terminal housing.
-
Grasp terminal at wire and push it gently into terminal housing -arrow-.
NOTE: By pushing terminal in direction of terminal housing, retaining tabs of terminal are lifted off the housing shoulder and can be released
using the release tool.