Tiguan 4Motion (5N1) L4-2.0L Turbo (CCTA) (2009)
‹› After assembling both housing halves, check seal / insulation - B - for correct seating at pass-through for both refrigerant lines - D - and - E -.
‹› Check seating of bracket - C - on both refrigerant lines - D - and - E - for correct seating.
‹› If heat protection insulation - B - is missing or not installed correctly, it can cause reduced performance of the A/C system (change of adjusted
control characteristics of expansion valve due to radiant heat).