Tiguan 4Motion (5N1) L4-2.0L Turbo (CCTA) (2009)
Evaporator Drain Tube: Testing and Inspection
Condensation Water Drain Hose on Heating and A/C Unit, Checking
-
Remove the trim panel inside the front passenger footwell.
The discharge point for the condensation water drain hose is located under the carpet and the noise insulating foam.
‹› The condensation water hose - 1 - must be able to be connected to connection of heating and A/C unit without pretension.
‹› Condensation water hose must sit securely on connection for condensation water hose on heating and A/C unit.