volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor Heater Before Catalytic Converter, Checking|Page 2488 > < Oxygen Sensor Heater Before Catalytic Converter, Checking|Page 2486
Page 2
background image

Checking primary voltage

-

Disconnect the Heated Oxygen Sensor (HO2S) (G39 ) electrical harness connector - 1 -.

-

Turn the ignition on. 

-

Using a multimeter connected to Ground, check the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector terminals 1 and 5 for
voltage.

Specified value: 2.45 to 2.99 Volts

If the specified value was obtained:

-

Using a multimeter connected to Ground, check the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector terminal 2 for voltage

Specified value: 2.25 to 2.79 Volts

If the specified value was obtained:

-

Using a multimeter connected to Ground, check the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector terminal 6 for voltage

Specified value: 3.25 to 3.79 Volts

If the specified value was obtained:

-

Replace the Heated Oxygen Sensor (HO2S) (G39).

If any of the above specified values were not obtained: 

Checking wiring

If the manufacturers test box is being used, perform the following step.

-

Install the test box. 

If the manufacturers test box is not being used, perform the following step.

-

Remove the Motronic Engine Control Module (ECM) ( J623).

-

Using a multimeter, check the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector terminals to the Motronic Engine Control
Module (ECM) (J623) electrical harness connector T94 terminals for an open circuit.

Oxygen Sensor Heater Before Catalytic Converter, Checking|Page 2488 > < Oxygen Sensor Heater Before Catalytic Converter, Checking|Page 2486