Measure the height of the calibration device, dimension -  H - (top edge platform - floor).

The distance dimension that was measured, the height of the calibration  device and the height of the center of the rearview camera lens must be
entered  in the vehicle diagnosis, testing and information system in " millimeters" during calibration.

Rear view camera system, calibrating --> [ Rearview Camera System, Calibrating ]. 

Rearview Camera System, Calibrating

‹› Observe the points regarding the preparation for calibrating --> [ Preliminary Work for Calibration ] 

-

Connect Vehicle Diagnosis, Testing and Information System.

-

In the vehicle diagnosis, testing and information system , select "Guided Functions" or "Guided Fault  Finding".

-

In the "Vehicle selection" menu, enter the corresponding  data for the vehicle and the following menu items one after another.

‹› Rearview Camera System

‹› Functions

‹› Rearview Camera System, Calibrating

The vehicle diagnosis, testing and information system guides the user through the calibration procedure.