Touareg V10-5.0L DSL Turbo (BKW) (2004)
Stabilizer Bar: Testing and Inspection
Rear Suspension
Separable Stabilizer Bar Hydraulic System, Checking Oil Level and Filling
Special tools, testers and auxiliary items required
‹› Vehicle diagnostic, test and information system (VAS 5051)
‹› Plastic spray bottle (commercially available)
-
Depressurize hydraulic system using the.
-
Remove left rear tail light.
-
Pull sealing plug - arrow - out of filler hole.
-
Cut tip - arrow - off plastic spray bottle.
Note dimension - X -, for example using adhesive tape.
Dimension X = 135 mm
-
Insert tube of plastic spray bottle into filler hole up to applied marking.