Operate remote control at short intervals, until a pressure of approximately  4 bar has built up.

-

Watch pressure drop on gauge. After 10 minutes the pressure must  not drop below a 3.0 bar decrease.

If the pressure drops:

-

Left fuel pump is faulty. Replace left fuel delivery unit --> [ Fuel Delivery Unit, Fuel Level Sensor and Suction Jet Pumps ] See: Powertrain
Management/Fuel Delivery and Air Induction/Fuel Pump/Service and Repair.

-

Open lever of pressure tester and let fuel flow back to fuel tank  through hose (V.A.G 1318/13).

-

Remove pressure gauge (V.A.G 1318) with adapters.