Leak Detection Pump, Checking|Page 6563 > < Leak Detection Pump, Checking|Page 6561
Page 4
background image

-

After the pressure has stabilized, set valve - D - to " Hold".

‹› The pressure must not drop below 20 mbar (8 in. H2O) after 5 minutes. 

If no pressure decrease can be determined, end diagnostic  mode 8 and check Leak Detection Pump (LDP) (V144) pressure  buildup --> [ Leak
Detection Pump, Checking Pressure Build-Up ] See: Leak Detection Pump, Checking Pressure Build-Up.

If pressure does not build up or if positive pressure  is not maintained for at least 5 minutes, locate leak as follows:

Allow engine to continue running in idle with diagnostic mode 8 activated. 

-

First check evaporative emission (EVAP) canister purge  regulator valve (N80) for leaks. Clamp off hose to evaporative emission (EVAP) canister
purge regulator valve (N80) with hose clamp - arrow -. 

-

Repeat pressure test by resetting valve - D - to " Test".

-

Observe pressure gauge and flow meter. If the flow quantity decreases  and the pressure climbs to 25 mbar (10 in. H2O), the fuel system is full. 

-

After the pressure has stabilized, set valve - D - to " Hold".

Leak Detection Pump, Checking|Page 6563 > < Leak Detection Pump, Checking|Page 6561