volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Fuel Pump, Checking|Page 6753 > < Fuel Pump, Checking|Page 6751
Page 7
background image

-

Then, close pressure gauge shut-off tap - arrow - (lever  perpendicular to direction of flow).

-

Operate remote control at short intervals, until a pressure of approximately  4 bar has built up.

CAUTION!
Danger of spray when opening the shut-off tap diesel extractor   (VAS 5226) must be connected.

-

If pressure builds up too high, lower excess pressure by carefully  opening the shut-off tap.

-

Watch pressure drop on gauge. After 10 minutes the pressure must  not drop below a 3.0 bar decrease.

If the pressure drops:

-

Check fuel lines and connections to fuel tank for leaks.

If no fault is detected in the wiring:

CAUTION!
Fuel supply lines are under pressure! Before opening fuel system,  connect diesel extractor (VAS 5226) and release  pressure.

-

In addition, wrap a cloth around the connection to catch fuel which  runs out.

-

Remove pressure gauge (V.A.G 1318) with adapters.

Check Right Pump Check Valve

Test Conditions

‹› Fuel pump relays - 1 - and - 2 - for  left and right fuel delivery units must be removed from their sockets.

Fuel Pump, Checking|Page 6753 > < Fuel Pump, Checking|Page 6751