Touareg V8-4.2L (AXQ) (2006)
-
Route hydraulic lines - 6 - and secure them with cable brackets - 8 - and foam strips - 7 -.
-
Press lines - 6 - onto connections - arrow a - until clips - 5 - snap downward - arrow b - and engage.
-
Make sure the lines - 7 - are securely attached to the connections - 4 - on the hydraulic pump.
-
Fold noise insulation - 3 - together and position bracket - 2 -.
-
Tighten bolts - 1 -, tightening specification: 60 Nm.