Touareg V8-4.2L (AXQ) (2006)
Terminal 3 + engine Ground (GND)of disconnected connector for Ignition Coil 1 with Power Output Stage (N70).
-
Operate starter and test ignition signal from Engine Control Module (ECM).
LED should flicker.
-
Repeat test at connectors for ignition coils cylinder 2 through 8.
-
Switch ignition off.
-
Insert fuses - 13 - and - 14 - in the fuse holder.
If LED flickers and voltage supply is OK:
-
Replace the respective ignition coil with power output stage.
-
Erase DTC memory of Engine Control Module (ECM) , Diagnostic mode 4: Reset/erase diagnostic data.
-
Generate readiness code.
If LED does not flicker:
-
Check wires according to wiring diagram.
Checking wiring
-
Connect test box to control module wiring harness , connect test box for wiring test.
-
Check wires between test box and 4-pin connector for open circuit according to wiring diagram.