Touareg V8-4.2L (BHX) (2004)
-
Route 1000 mm (3 ft.) .5 mm wire down alongside of center air distribution duct (black arrow) to Access/Start Control Module -J518- as shown.
-
Splice 1000 mm (3 ft.) bulk .5 mm wire to new terminal wire Part No: 000 979 003 using butt splice - Part No: 111 971 941A (see VAS 1978 Wiring
Harness Repair Manual for instructions).
-
Insert terminal into cavity 62 of Access/Start Control Module -J518- connector.
-
Reinstall hard-shell housing on Access/Start Control Module -J51B- connector.
-
Secure wire leading to (Access/Start Control Module -J518-) as necessary (to eliminate any rattles).
-
Reinstall Access/Start Control Module -J518-.
-
Finish new antenna wire routing along existing harness (white arrows shown in 57-A091) to grommet.
-
Secure wire into position with tie straps and tape.
-
Trim excess wire so that wire terminates at grommet.
Assembly:
-
Install center storage bin/vent assembly.
Tip:
Ensure that all (center storage bin/vent assembly) clips are located and reinstalled on assembly prior to installation.
-
Connect wiring harnesses (depending on vehicle equipment) to appropriate switches in switch strip.