Touareg 2 V6-3.6L (BHK) (2008)
Installing
Installation is carried out in the reverse order, when doing this note the following:
-
Initiate Basic Setting function with Diagnostic Operation System (VAS 5051B). Refer to--> [ Climatronic A/C System with Automatic Control,
Checking and Adjusting ] See: Testing and Inspection/Climatronic A/C System with Automatic Control, Checking and Adjusting.
Rear Blower Regulation
Door Motors
Rear Blower Regulation
Removing
-
Bring rear heating and air conditioning unit into service position. Refer to --> [ Second Rear Heating and A/C Unit, Service Position ] See:
Testing and Inspection/Second Rear Heating and A/C Unit, Service Position
-
Disconnect connector - 1 - at Rear Blower Regulation Motor (Bitron) (V306).
-
Lift tab - 2 - slightly and rotate Rear Blower Regulation Motor (Bitron) (V306) in - direction of arrow -.
-
Remove the Rear Blower Regulation Motor (Bitron) (V306) from the heating and air conditioning unit
Installing
Install in reverse order.
‹› Condensation water hose to valve must not be kinked or pinched. Refer to --> [ Rear Condensation Water Hose with Valve, Checking ] See:
Evaporator Drain Tube/Testing and Inspection/Rear Condensation Water Hose with Valve, Checking.
Right Footwell Door and Right Temperature Door
Door Motors
Right Footwell Door and Right Temperature Door
Removing
‹› Right lower retaining plate on the A/C unit removed.
-
Remove bolts - 3 -.