Touareg 2 V6-3.6L (BHK) (2008)
-
Disconnect connectors.
-
Pull retaining plate and control motors out downwards.
Right Lower A/C Unit Retaining Plate
Right Lower A/C Unit Retaining Plate
Removing
-
Initiate control motor Basic Setting function with Diagnostic Operation System (Vas 5051B). Refer to --> [ Climatronic A/C System with
Automatic Control, Checking and Adjusting ] See: Testing and Inspection/Climatronic A/C System with Automatic Control, Checking and
Adjusting.
-
When SF appears on the left of the Climatronic operating display, switch ignition off.
‹› Control motors can only be re-installed in the service position after removal.
-
Remove the right lower dash panel trim.
-
Remove bolts - 3 -.
‹› To remove the retaining plate the bolts - 1 - are not loosened or removed, they are used for guiding the retaining plate.
‹› Mark the connections for each motor to prevent confusing them.
-
Disconnect connectors.
-
Pull retaining plate and control motors out downwards.
Installing
Installation is carried out in the reverse order, when doing this note the following:
-
When installing, make sure control motor drivers - A - are pushed into retainers - B -.