volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Leak Detection Pump, Evaporative System|Testing and Inspection|Page 3032 > < Evaporative Emission Control Canister|Description and Operation
Page 1
background image

Leak Detection Pump: Testing and Inspection

Leak Detection Pump, Checking

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Test requirements

‹› The Leak Detection Pump (LDP) (V144) fuse  OK. 

‹› The ignition switched off.

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer  to --> [ Preliminary Check ] See: Computers and Control Systems/Testing
and Inspection/Scan Tool Testing and Procedures/Preliminary Check

Start diagnosis

‹› The voltage for the Leak Detection Pump (LDP) (-V144-) is supplied via the Motronic Engine Control Module (ECM)  Power Supply Relay

(J271).

-

Remove the left rear wheel housing liner.

-

Disconnect the Leak Detection Pump (LDP) (V144) electrical harness connector - 3 -.

Checking internal resistance

-

Using a Multimeter, check the Leak  Detection Pump (LDP) (V144) for resistance as follows: 

Leak Detection Pump, Evaporative System|Testing and Inspection|Page 3032 > < Evaporative Emission Control Canister|Description and Operation