volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Fuel Pressure Regulator Valve, Checking|Page 3058 > < Fuel Pressure Regulator Valve, Checking|Page 3056
Page 8
background image

-

Watch pressure drop on gauge. After 10 minutes pressure must not  drop below a 4.0 bar decrease.

If pressure drops below 4.0 bar:

-

Operate Hand held remote starter (jumper) while  doing this, observe display of pressure tester.

Fuel pressure must increase up to a maximum pressure of 6 bar.

-

Release control button of Hand held remote starter (jumper)   and immediately close shut-off valve of pressure tester. Then  lever the points
perpendicular to flow direction - arrow -. 

‹› When releasing control button of Hand held remote starter  (jumper), fuel pressure decreases to approx. 5.6 bar.

If pressure drops below 4.0 bar again:

(Leak on fuel tank side)

-

Check connections to fuel tank for leaks.

If no malfunction can be found:

-

Check fuel filter for leaks.

-

Check fuel line to sensor flange for leaks.

-

Check all additional fuel lines in fuel tank for leaks.

If no malfunctions are found on fuel line:

-

Pressure relief valve in fuel delivery unit flange faulty.

-

Replace sensor flange which contains the pressure relief valve. 

Delivery Rate, Checking

-

Remove high pressure in fuel system --> [ Fuel System ] See: Description and Operation/Fuel System.

CAUTION!
Fuel supply line is under pressure! Wear protective goggles and protective  clothing to prevent injuries and contact with skin. Before
removing from hose  connection wrap a cloth around the connection. Then release pressure by carefully  loosening the union nut.

Test sequence

Observe Safety Precautions: --> [ Safety Precautions ] See: Description and Operation/Fuel System

Observe Clean Working Conditions: --> [ Clean Working Conditions ] See: Description and Operation/Fuel System

Fuel Pressure Regulator Valve, Checking|Page 3058 > < Fuel Pressure Regulator Valve, Checking|Page 3056