If the delivery rate has been attained but nevertheless you suspect  a fuel supply system malfunction (e.g. intermittent failure of fuel supply  system).

-

Check FP current draw. Refer to --> [ Current Draw, Checking ].

Current Draw, Checking

-

Check the current draw of the fuel pump as follows:

-

Reconnect all disconnected fuel lines.

-

Connect multi meter (VAG 1715) with  electrical current probe to wire of 4 pin connector terminal - 1 - -  arrow - from wiring harness to Fuel
Pump (FP) unit, right.

-

Start the engine and run at idle speed.

-

Measure current draw of fuel pump. Specified value: max. 11 amps. 

If the current draw is exceeded:

-

FP faulty, replace fuel delivery unit. Refer to --> [ Fuel Delivery Unit and Fuel Level Sensor ] See: Fuel Pump/Service and Repair/Fuel Delivery
Unit and Fuel Level Sensor. 

‹› If malfunction in fuel system is sporadic, test can also be performed  during a road test, but a second person is required.