Touareg 2 V6-3.6L (BHK) (2008)
-
Disconnect connector from Fuel Pump (FP) control module (J538) - 5 -.
-
Disconnect harness connector - 3 - from flange of fuel delivery unit.
-
Connect remote control (VAG 1348/3A) with adapter cables from connector test kit (VAG 1594C) to terminal - 1 (+) - of FP and to terminal - 3
(+) - of harness connector of FP control module (J538).
-
Connect terminals - 4 (-) - of harness connector and - 4 (-) - of FP using an adapter cable from connector test kit (VAG 1594C).
CAUTION!
Fuel supply line is under pressure! Wear protective goggles and protective clothing to prevent injuries and contact with skin. Before