Touareg 2 V6-3.6L (BHK) (2008)
removing from hose connection wrap a cloth around the connection. Then release pressure by carefully loosening the union nut.
-
Lay a cloth around threaded connection and loosen union nut - arrow - from fuel supply hose. To do so, counter hold on fuel supply line using a
wrench.
-
Install pressure gauge (VAG 1318) with adapter (VAG 1318/6), adapter (VAG 1318/7) and adapter (VAG 1318/12) as shown.
CAUTION!
Danger of spraying when opening shut-off valve; wear protective goggles and protective clothing to prevent injuries and contact with
skin. Hold container in front of free connection of pressure measuring device.
-
Open shut-off valve of pressure gauge set. Lever will point in direction of flow - A -.
-
Switch ignition on.
‹› A second mechanic is needed for the following task.
-
Hold adapter (VAG 1318/6) over a measuring container.
-
Operate remote control (VAG 1348/3A). Slowly close shut-off tap, until pressure gauge shows 4 bar. From this point on do not move position of
shut-off tap.
-
Empty measuring container.
-
Operate remote control for 15 seconds: At least 350 cm3 fuel per 15 seconds must be delivered.
If the minimum delivery rate is not attained:
-
Check the fuel lines for possible restrictions (kinks) or blockages.