volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

All Technical Service Bulletins:|878406 > < A/C Evaporator - Repair
Page 1
background image

Evaporator Core: All Technical Service Bulletins
A/C Evaporator - Water Leaking From Vents

 SUBJECT:

A/C Evaporator - water leaking
GROUP

87

NUMBER

90-01 March 31, 1990

MODEL(S):

Vanagon/ Vanagon Camper Waterboxer all M.Y.
Water may come out of A/C vents if the evaporator drain tray does not drain properly. This may be caused by:

^

A missing or clogged drain valve. A drain valve must be installed on the drain hose to prevent water from being drawn back into the evaporator
housing via vacuum created by the blower motors.

1.

For 1/2" o/d hose, use drain valve Part No. 253 260 180

2.

For 3/8" o/d hose, use drain valve Part No. 431 260 1 65

Clogged drain valves should be cleaned of all foreign matter and must be reinstalled.

A water drain valve has been installed in production as of 5/88. VIN 25JH093520 25JG095871

CAUTION

Part numbers are for reference only. Always check with your Parts Department for latest information.

All Technical Service Bulletins:|878406 > < A/C Evaporator - Repair