volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Refrigerant > < Flap Housing, Disassembling/Assembling|Page 3762
Page 1
background image

Hose/Line HVAC: Technical Service Bulletins
A/C Compressor - Repairing Loose Hose Fittings

Applies To

Vanagon Waterboxer

1983-84

Group

87
Subject

A/C System

Part Identifier 8734
Key Points

Repairing loose hose fittings at A/C compressor

C

Number

84-03

October 1, 1984
In response to complaints of loose A/C hose fittings at 
the A/C compressor, install the following repair 

kit:

P/N 255 272 004 

Kit includes:

P/N 255 272 741 low pressure (suction) fitting P/N 255 272 741 A high pressure (discharge) fitting

WARNING

Always wear safety goggles when charging or discharging system. Be sure work area is well ventilated. Refrigerant-12 is heavier than air and can
accumulate in areas of poor air circulation..

Avoid inhaling fumes when using flame type leak detector. Refrigerant-12 becomes poisonous gas after coming into contact with open flame.

CAUTION

Always discharge refrigerant from air conditioner system before loosening connections, hoses, etc.

Work sequence

-

discharge A/C system

-

remove both A/C hose fittings from A/C compressor

-

cut fittings from hoses at end of crimp

-

discard hose fittings

-

insert new fittings into hoses approximately 37.0 mm (1.5 inches)

-

clamp fittings to hose using size 8 refrigerant hose clamps (obtain locally )

-

install new O-rings to fittings

-

install fittings on compressor and tighten

^

low pressure hose 34.0 N-m ( 25.0 ft.lbs. )

^

high pressure hose 30.0 N-m (22.0 ft.lbs.)

-

evacuate and recharge A/C system

Suggested repair time:

115 T.U.

Note

Plug all openings in system when removing/ replacing parts. This prevents entry of dirt and moisture which may foul system.

Refrigerant > < Flap Housing, Disassembling/Assembling|Page 3762