Vanagon F4-1915cc 1.9L (Water Cooled) (1983)
Ignition Control Module: All Technical Service Bulletins
Engine - Stops Running
GROUP
28
NUMBER
87-05 July 31, 1987
MODEL(S):
All, all m..y.
SUBJECT:
Engine stops running - ignition control unit
Metal shavings or other debris between the ignition control unit and heat sink can cause stress which may damage internal circuits of the control unit:
^